Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd

Transformers: primary D / secondary d

Information

This package contains transformers primary D connected / secondary d connected in all possible vector groups.

Extends from Modelica.Icons.VariantsPackage (Icon for package containing variants).

Package Content

Name Description
Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd00 Dd00 Transformer Dd0
Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd02 Dd02 Transformer Dd2
Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd04 Dd04 Transformer Dd4
Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd06 Dd06 Transformer Dd6
Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd08 Dd08 Transformer Dd8
Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd10 Dd10 Transformer Dd10

Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd00 Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd00

Transformer Dd0

Information

Transformer Dd0
Typical parameters see: PartialBasicTransformer

Extends from QuasiStationary.Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).

Parameters

NameDescription
nRatio primary voltage (line-to-line) / secondary voltage (line-to-line)
useThermalPortEnable / disable (=fixed temperatures) thermal port
Operational temperatures
T1OperationalOperational temperature of primary resistance [K]
T2OperationalOperational temperature of secondary resistance [K]
Nominal resistances and inductances
R1Primary resistance per phase at TRef [Ohm]
T1RefReference temperature of primary resistance [K]
alpha20_1Temperature coefficient of primary resistance at 20 degC [1/K]
L1sigmaPrimary stray inductance per phase [H]
R2Secondary resistance per phase at TRef [Ohm]
T2RefReference temperature of secondary resistance [K]
alpha20_2Temperature coefficient of secondary resistance at 20 degC [1/K]
L2sigmaSecondary stray inductance per phase [H]

Connectors

NameDescription
plug1Primary plug
plug2Secondary plug
thermalPort 

Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd02 Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd02

Transformer Dd2

Information

Transformer Dd2
Typical parameters see: PartialBasicTransformer

Extends from QuasiStationary.Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).

Parameters

NameDescription
nRatio primary voltage (line-to-line) / secondary voltage (line-to-line)
useThermalPortEnable / disable (=fixed temperatures) thermal port
Operational temperatures
T1OperationalOperational temperature of primary resistance [K]
T2OperationalOperational temperature of secondary resistance [K]
Nominal resistances and inductances
R1Primary resistance per phase at TRef [Ohm]
T1RefReference temperature of primary resistance [K]
alpha20_1Temperature coefficient of primary resistance at 20 degC [1/K]
L1sigmaPrimary stray inductance per phase [H]
R2Secondary resistance per phase at TRef [Ohm]
T2RefReference temperature of secondary resistance [K]
alpha20_2Temperature coefficient of secondary resistance at 20 degC [1/K]
L2sigmaSecondary stray inductance per phase [H]

Connectors

NameDescription
plug1Primary plug
plug2Secondary plug
thermalPort 

Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd04 Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd04

Transformer Dd4

Information

Transformer Dd4
Typical parameters see: PartialBasicTransformer

Extends from QuasiStationary.Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).

Parameters

NameDescription
nRatio primary voltage (line-to-line) / secondary voltage (line-to-line)
useThermalPortEnable / disable (=fixed temperatures) thermal port
Operational temperatures
T1OperationalOperational temperature of primary resistance [K]
T2OperationalOperational temperature of secondary resistance [K]
Nominal resistances and inductances
R1Primary resistance per phase at TRef [Ohm]
T1RefReference temperature of primary resistance [K]
alpha20_1Temperature coefficient of primary resistance at 20 degC [1/K]
L1sigmaPrimary stray inductance per phase [H]
R2Secondary resistance per phase at TRef [Ohm]
T2RefReference temperature of secondary resistance [K]
alpha20_2Temperature coefficient of secondary resistance at 20 degC [1/K]
L2sigmaSecondary stray inductance per phase [H]

Connectors

NameDescription
plug1Primary plug
plug2Secondary plug
thermalPort 

Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd06 Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd06

Transformer Dd6

Information

Transformer Dd6
Typical parameters see: PartialBasicTransformer

Extends from QuasiStationary.Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).

Parameters

NameDescription
nRatio primary voltage (line-to-line) / secondary voltage (line-to-line)
useThermalPortEnable / disable (=fixed temperatures) thermal port
Operational temperatures
T1OperationalOperational temperature of primary resistance [K]
T2OperationalOperational temperature of secondary resistance [K]
Nominal resistances and inductances
R1Primary resistance per phase at TRef [Ohm]
T1RefReference temperature of primary resistance [K]
alpha20_1Temperature coefficient of primary resistance at 20 degC [1/K]
L1sigmaPrimary stray inductance per phase [H]
R2Secondary resistance per phase at TRef [Ohm]
T2RefReference temperature of secondary resistance [K]
alpha20_2Temperature coefficient of secondary resistance at 20 degC [1/K]
L2sigmaSecondary stray inductance per phase [H]

Connectors

NameDescription
plug1Primary plug
plug2Secondary plug
thermalPort 

Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd08 Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd08

Transformer Dd8

Information

Transformer Dd8
Typical parameters see: PartialBasicTransformer

Extends from QuasiStationary.Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).

Parameters

NameDescription
nRatio primary voltage (line-to-line) / secondary voltage (line-to-line)
useThermalPortEnable / disable (=fixed temperatures) thermal port
Operational temperatures
T1OperationalOperational temperature of primary resistance [K]
T2OperationalOperational temperature of secondary resistance [K]
Nominal resistances and inductances
R1Primary resistance per phase at TRef [Ohm]
T1RefReference temperature of primary resistance [K]
alpha20_1Temperature coefficient of primary resistance at 20 degC [1/K]
L1sigmaPrimary stray inductance per phase [H]
R2Secondary resistance per phase at TRef [Ohm]
T2RefReference temperature of secondary resistance [K]
alpha20_2Temperature coefficient of secondary resistance at 20 degC [1/K]
L2sigmaSecondary stray inductance per phase [H]

Connectors

NameDescription
plug1Primary plug
plug2Secondary plug
thermalPort 

Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd10 Modelica.Electrical.QuasiStationary.Machines.BasicMachines.Transformers.Dd.Dd10

Transformer Dd10

Information

Transformer Dd10
Typical parameters see: PartialBasicTransformer

Extends from QuasiStationary.Machines.Interfaces.PartialBasicTransformer (Partial model of three-phase transformer).

Parameters

NameDescription
nRatio primary voltage (line-to-line) / secondary voltage (line-to-line)
useThermalPortEnable / disable (=fixed temperatures) thermal port
Operational temperatures
T1OperationalOperational temperature of primary resistance [K]
T2OperationalOperational temperature of secondary resistance [K]
Nominal resistances and inductances
R1Primary resistance per phase at TRef [Ohm]
T1RefReference temperature of primary resistance [K]
alpha20_1Temperature coefficient of primary resistance at 20 degC [1/K]
L1sigmaPrimary stray inductance per phase [H]
R2Secondary resistance per phase at TRef [Ohm]
T2RefReference temperature of secondary resistance [K]
alpha20_2Temperature coefficient of secondary resistance at 20 degC [1/K]
L2sigmaSecondary stray inductance per phase [H]

Connectors

NameDescription
plug1Primary plug
plug2Secondary plug
thermalPort 
Automatically generated Tue Apr 05 09:36:29 2016.