Modelica.Fluid.Dissipation.HeatTransfer.General

Information

General heat transfer

Approximated forced convection

Approximate calculation of the mean convective heat transfer coefficient kc for forced convection with a fully developed fluid flow in a turbulent regime. See more information.

Extends from Modelica.Icons.VariantsPackage (Icon for package containing variants).

Package Content

Name Description
Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection kc_approxForcedConvection Mean convective heat transfer coefficient for forced convection | approximation | turbulent regime | hydrodynamically developed fluid flow
Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_KC kc_approxForcedConvection_KC Mean convective heat transfer coefficient for forced convection | approximation | turbulent regime | hydrodynamically developed fluid flow
Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_IN_con kc_approxForcedConvection_IN_con Input record for function kc_approxForcedConvection and kc_approxForcedConvection_KC
Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_IN_var kc_approxForcedConvection_IN_var Input record for function kc_approxForcedConvection and kc_approxForcedConvection_KC

Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection

Mean convective heat transfer coefficient for forced convection | approximation | turbulent regime | hydrodynamically developed fluid flow

Information

Approximate calculation of the mean convective heat transfer coefficient kc for forced convection with a fully developed fluid flow in a turbulent regime.

A detailed documentation for this convective heat transfer calculation can be found in its underlying function kc_approxForcedConvection_KC . Note that additionally a failure status is observed in this function to check if the intended boundary conditions are fulfilled. See more information .

Extends from Modelica.Icons.Function (Icon for functions).

Inputs

NameDescription
Constant inputs
IN_conInput record for function kc_approxForcedConvection
Variable inputs
IN_varInput record for function kc_approxForcedConvection

Outputs

NameDescription
Output
kcConvective heat transfer coefficient [W/(m2.K)]
PrPrandtl number [1]
ReReynolds number [1]
NuNusselt number [1]
failureStatus0== boundary conditions fulfilled | 1== failure >> check if still meaningful results

Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_KC Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_KC

Mean convective heat transfer coefficient for forced convection | approximation | turbulent regime | hydrodynamically developed fluid flow

Information

Approximate calculation of the mean convective heat transfer coefficient kc for forced convection with a fully developed fluid flow in a turbulent regime. See more information .

Extends from Modelica.Icons.Function (Icon for functions).

Inputs

NameDescription
Constant inputs
IN_conInput record for function kc_approxForcedConvection_KC
Variable inputs
IN_varInput record for function kc_approxForcedConvection_KC

Outputs

NameDescription
kcOutput for function kc_approxForcedConvection_KC [W/(m2.K)]

Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_IN_con Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_IN_con

Input record for function kc_approxForcedConvection and kc_approxForcedConvection_KC

Information

This record is used as input record for the heat transfer function kc_approxForcedConvection and kc_approxForcedConvection_KC.

Extends from Modelica.Fluid.Dissipation.Utilities.Records.HeatTransfer.General (Input for generic correlation).

Parameters

NameDescription
Generic variables
targetTarget correlation
A_crossCross sectional area [m2]
perimeterWetted perimeter [m]
exp_PrExponent for Prandtl number w.r.t. Dittus/Boelter | 0.4 for heating | 0.3 for cooling

Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_IN_var Modelica.Fluid.Dissipation.HeatTransfer.General.kc_approxForcedConvection_IN_var

Input record for function kc_approxForcedConvection and kc_approxForcedConvection_KC

Information

This record is used as input record for the heat transfer function kc_approxForcedConvection and kc_approxForcedConvection_KC.

Extends from Modelica.Fluid.Dissipation.Utilities.Records.General.FluidProperties (Base record for fluid properties).

Parameters

NameDescription
Fluid properties
cpSpecific heat capacity of fluid at constant pressure [J/(kg.K)]
etaDynamic viscosity of fluid [Pa.s]
lambdaThermal conductivity of fluid [W/(m.K)]
rhoDensity of fluid [kg/m3]
eta_wallDynamic viscosity of fluid at wall temperature [Pa.s]
Input