Modelica.Electrical.MultiPhase.Examples

Multiphase test examples

Information

This package contains test examples of analog electrical multiphase circuits.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
Modelica.Electrical.MultiPhase.Examples.TransformerYY TransformerYY Test example with multiphase components
Modelica.Electrical.MultiPhase.Examples.TransformerYD TransformerYD Test example with multiphase components
Modelica.Electrical.MultiPhase.Examples.Rectifier Rectifier Test example with multiphase components
Modelica.Electrical.MultiPhase.Examples.TestSensors TestSensors  

Modelica.Electrical.MultiPhase.Examples.TransformerYY Modelica.Electrical.MultiPhase.Examples.TransformerYY

Test example with multiphase components

Information

Test example with multiphase components:
Star-connected voltage source feeds via a Y-Y-transformer with internal impedance (RT, LT) a load resistor RT.
Using f=5 Hz LT=3mH defines nominal voltage drop of approximately 10 %.
Simulate for 1 second (2 periods) and compare voltages and currents of source, transformer and load.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
VAmplitude of Star-Voltage [V]
fFrequency [Hz]
LmTransformer main inductance [H]
LTTransformer stray inductance [H]
RTTransformer resistance [Ohm]
RLLoad Resistance [Ohm]
nTTransformer ratio

Modelica.Electrical.MultiPhase.Examples.TransformerYD Modelica.Electrical.MultiPhase.Examples.TransformerYD

Test example with multiphase components

Information

Test example with multiphase components:
Star-connected voltage source feeds via a Y-D-transformer with internal impedance (RT, LT) a load resistor RT.
Using f=5 Hz LT=3mH defines nominal voltage drop of approximately 10 %.
Simulate for 1 second (2 periods) and compare voltages and currents of source, transformer and load.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
VAmplitude of Star-Voltage [V]
fFrequency [Hz]
LmTransformer main inductance [H]
LTTransformer stray inductance [H]
RTTransformer resistance [Ohm]
RLLoad Resistance [Ohm]
nTTransformer ratio

Modelica.Electrical.MultiPhase.Examples.Rectifier Modelica.Electrical.MultiPhase.Examples.Rectifier

Test example with multiphase components

Information

Test example with multiphase components:
Star-connected voltage source feeds via a line reactor a diode bridge rectifier with a DC burden.
Using f=5 Hz, simulate for 1 second (2 periods) and compare voltages and currents of source and DC burden, neglecting initial transient.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
mNumber of phases
VAmplitude of Star-Voltage [V]
fFrequency [Hz]
LLine Inductance [H]
RLLoad Resistance [Ohm]
CTotal DC-Capacitance [F]
REEarthing Resistance [Ohm]
RonClosed diode resistance [Ohm]
GoffOpened diode conductance [S]
VkneeThreshold diode voltage [V]

Modelica.Electrical.MultiPhase.Examples.TestSensors Modelica.Electrical.MultiPhase.Examples.TestSensors

Information

Test multiphase quasiRMS sensors: A sinusoidal source feeds a load consisting of resistor and inductor.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

NameDescription
VRMSNominal RMS voltage per phase [V]
fFrequency [Hz]
RLoad resistance [Ohm]
LLoad inductance [H]
Automatically generated Tue Apr 05 09:36:23 2016.